Lithuania
Export

Solid fuel steam boilers FAKO

KMRs

Steam boilers equipped with fixed grid, whose efficiency range is from 80 to 880 kg/h and pressure 1 or 6 bar, are dedicated to customers searching for reliable and simple in operation appliances to combust solid fuels.
The characteristic features of such boilers are their simple construction, assuring non-failure operation for many years and facility in adjusting them to combust different types of fuel.
Thanks to adequately selected proportion of heat exchange areas guaranteeing optimum combustion process and to its minimum exhaust flow resistance, what we receive is a high-performance boiler of low fuel consumption

  • Steam boiler KMRs Steam boiler KMRs
  • Steam boiler KMRs Steam boiler KMRs
     
Dimensions, mm
A B C D E F H K L M N Z dn
KMRs-270 1750 1770 2070 1600 400 500 1060 300 200 400 350 300 50
KMRs-370 2000 1770 2070 1660 550 500 1060 300 400 400 350 400 50
KMRs-510 2100 1980 2370 1800 550 750 1230 300 400 626 326 400 65
KMRs-690 2250 2340 2470 2220 1100 860 1230 300 600 722 380 400 80
KMRs-880 2750 2340 2470 2220 1100 860 1230 300 600 722 380 400 80

1 – Boilers trunk
2 – Front review door
3 – Back review door
4 – Steam consumption valve dn
5 – Condensate retrace valve dn=32
6 – Desalting valve dn=15
7 – Washout hole
8 – Back washout hole door
9 – Front loading door
10 – Smoke-box
11 – Foundation
12 – Ash pits door
13 – Washout hole with a draining connector dn=20
14 – Gust fan
15 – Safety valve d1xd2 – p1 = 6 bar
16 – Water level sensor
17 – Water level safety sensor
18 – Shield of water level sensor
19 – Shield of water level safety sensor
20 – Manometer
21 – Aeration valve
22 – Fluid level gauge
23 – Washout hole

Technical profile
Model KMRs 270 KMRs 370 KMRs 510 KMRs 690 KMRs 880
Rated power, kW 185 250 350 470 600
Steam capacity, kg/h 286 387 542 728 930
Heating surface, m² 21 27 32 46 57
Max.working pressure, bar 6
Max.working temperature, °C 165
Exhaust gases temp.in the smoke-box, °C 240
Required draught in the smoke-box, Pa 50 55 55 55 55
Boilers water capacity, m³ 2,1 2,3 2,9 4,1 5,0
Boilers mass without grate, kg 3300 3700 4100 6100 7200

EKPs

 
Steam boilers with retort furnace, whose efficiency range is from 270 to 2900 kg/h and pressure is 1 or 6 bar, are dedicated to customers searching for modern and ecological solutions in solid fuel combustion.
The boilers have been equipped with an automatic control system of the combustion process, thanks to which the furnace is provided with constant flame, saving the need of frequent fire starting, while fuel is dosed through a conveying screw depending on target temperature.
Thanks to retort furnace it is possible to combust as much fuel as is needed to maintain target working parameters, allowing thus to acquire performance at the level of 92% and to reduce fuel consumption significantly.

  • Automatic biomass fired steam boiler EKPs Automatic biomass fired steam boiler EKPs
  • Automatic biomass fired steam boiler EKPs Automatic biomass fired steam boiler EKPs
     
Dimensions, mm
A B C D E F G H I M N J dn K X Y Z
EKPs-270 1750 1770 2070 1600 400 500 1060 300 200 400 350 300 50 500 1700 1200 1200
EKPs-370 2000 1770 2070 1660 550 500 1060 300 400 400 350 400 50 500 1700 1200 1200
EKPs-510 2100 1980 2370 1800 550 750 1230 300 400 626 326 400 65 500 1700 1480 1200
EKPs-690 2250 2340 2470 2220 1100 860 1230 300 600 722 380 400 80 520 1700 1580 1200
EKPs-880 2750 2340 2470 2220 1100 860 1230 300 600 722 380 400 80 530 1700 1580 1200

1 – Boilers trunk
2 – Front review door
3 – Back review door
4 – Steam consumption valve dn
5 – Condensate retrace valve dn=32
6 – Desalting valve dn=15
7 – Washout hole
8 – Back washout hole door
9 – Front loading door
10 – Smoke-box
11 – Foundation
12 – Ash pits door
13 – Washout hole with a draining connector dn=20
14 – Safety valve d1xd2 – p1 = 6 bar
15 – Water level sensor
16 – Water level safety sensor
17 – Shield of water level sensor
18 – Shield of water level safety sensor
19 – Manometer
20 – Aeration valve
21 – Fluid level gauge
22 – Washout hole
23 – Fuel bunker
24 – Screw conveyor
25 – Motor-reducer
26 – Secondary air fan
27 – Original air fan
28 – Pour joint

Technical profile
Model EKPs 270 EKPs 370 EKPs 510 EKPs 690 EKPs 880
Rated power, kW 185 250 350 470 600
Steam capacity, kg/h 286 387 542 728 930
Heating surface, m² 21 27 32 46 57
Max.working pressure, bar 6
Max.working temperature, °C 165
Exhaust gases temp.in the smoke-box, °C 240
Required draught in the smoke-box, Pa 50 55 55 55 55
Boilers water capacity, m³ 2,1 2,3 2,9 4,1 5,0
Boilers mass without grate, kg 3300 3700 4100 6100 7200
Director
Lygaudas Rinkevičius
+370 612 13090
Production director
Vidmantas Kazakevičius
+370 615 98523
Administrator
Lina Butrimavičienė
+370 646 12447

UT series industrial water heating boilers for solid fuel

Capasity: 50 kW to 500 kW

Fuel: pellets, sawdust, woodchips, coal, firewood,

briquettes.

Industrial water heating boilers UT β with volcanic fuel supply

Capasity: 200 kW to 1 MW

Fuel: sawdust, wood chips, firewood, waste wood, briquettes, coal.

Industrial water heating boilers UT β with automatic feeding system

Capasity: 320 kW to 1 MW

Fuel: firewood, waste wood, briquettes, coal.

 

Industrial water heating boilers UT for solid fuel with automatic pellet burner

Capasity: 50 kW to 1 MW

Fuel: firewood, waste wood, briquettes, coal.

 

Steam boilers